vmat plan to sw imrt plan converter Search Results


90
TomoTherapy imrt plan
Dose distribution maps of patient 3 treated with TBI. The radiotherapy plan of this patient was <t>helical</t> <t>tomotherapy-TBI.</t> The red range in the map is the isodose line of 13.2 Gy. The yellow range is the isodose line of 12.0 Gy. The yellow-green range is the isodose line of 11.4 Gy. The green range is the isodose line of 10.8 Gy. The blue range is the isodose line of 8.0 Gy. TBI, total body irradiation.
Imrt Plan, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/imrt plan/product/TomoTherapy
Average 90 stars, based on 1 article reviews
imrt plan - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

86
Varian Medical vmat imrt treatment plans
Dose distribution maps of patient 3 treated with TBI. The radiotherapy plan of this patient was <t>helical</t> <t>tomotherapy-TBI.</t> The red range in the map is the isodose line of 13.2 Gy. The yellow range is the isodose line of 12.0 Gy. The yellow-green range is the isodose line of 11.4 Gy. The green range is the isodose line of 10.8 Gy. The blue range is the isodose line of 8.0 Gy. TBI, total body irradiation.
Vmat Imrt Treatment Plans, supplied by Varian Medical, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vmat imrt treatment plans/product/Varian Medical
Average 86 stars, based on 1 article reviews
vmat imrt treatment plans - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

90
IBA Dosimetry matrixx evolution™ 2d ionization chamber array
Dose distribution maps of patient 3 treated with TBI. The radiotherapy plan of this patient was <t>helical</t> <t>tomotherapy-TBI.</t> The red range in the map is the isodose line of 13.2 Gy. The yellow range is the isodose line of 12.0 Gy. The yellow-green range is the isodose line of 11.4 Gy. The green range is the isodose line of 10.8 Gy. The blue range is the isodose line of 8.0 Gy. TBI, total body irradiation.
Matrixx Evolution™ 2d Ionization Chamber Array, supplied by IBA Dosimetry, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/matrixx evolution™ 2d ionization chamber array/product/IBA Dosimetry
Average 90 stars, based on 1 article reviews
matrixx evolution™ 2d ionization chamber array - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

86
Elekta vmat imrt treatment plans
Dose distribution maps of patient 3 treated with TBI. The radiotherapy plan of this patient was <t>helical</t> <t>tomotherapy-TBI.</t> The red range in the map is the isodose line of 13.2 Gy. The yellow range is the isodose line of 12.0 Gy. The yellow-green range is the isodose line of 11.4 Gy. The green range is the isodose line of 10.8 Gy. The blue range is the isodose line of 8.0 Gy. TBI, total body irradiation.
Vmat Imrt Treatment Plans, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/vmat imrt treatment plans/product/Elekta
Average 86 stars, based on 1 article reviews
vmat imrt treatment plans - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

90
TomoTherapy step&shoot-imrt
Structure definition and dose distribution for one MPM patient (Step & Shoot <t>IMRT).</t> In the coronar projection ( a ), the inclusion of the EPP incisions into the target volume are marked by white arrows. The sagittal projection ( b ) shows the caudal extension of the target volume with sparing of the liver and the kidney. In the two transverse slices the sparing of the heart ( c ) and again liver and kidney ( d ) can be seen
Step&Shoot Imrt, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/step&shoot-imrt/product/TomoTherapy
Average 90 stars, based on 1 article reviews
step&shoot-imrt - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
SAS institute step-and-shoot imrt
Structure definition and dose distribution for one MPM patient (Step & Shoot <t>IMRT).</t> In the coronar projection ( a ), the inclusion of the EPP incisions into the target volume are marked by white arrows. The sagittal projection ( b ) shows the caudal extension of the target volume with sparing of the liver and the kidney. In the two transverse slices the sparing of the heart ( c ) and again liver and kidney ( d ) can be seen
Step And Shoot Imrt, supplied by SAS institute, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/step-and-shoot imrt/product/SAS institute
Average 90 stars, based on 1 article reviews
step-and-shoot imrt - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
TomoTherapy helical tomotherapy
Structure definition and dose distribution for one MPM patient (Step & Shoot <t>IMRT).</t> In the coronar projection ( a ), the inclusion of the EPP incisions into the target volume are marked by white arrows. The sagittal projection ( b ) shows the caudal extension of the target volume with sparing of the liver and the kidney. In the two transverse slices the sparing of the heart ( c ) and again liver and kidney ( d ) can be seen
Helical Tomotherapy, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/helical tomotherapy/product/TomoTherapy
Average 90 stars, based on 1 article reviews
helical tomotherapy - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
TomoTherapy fixed-field imrt
Typical dose distributions of the five plans in cervical cancer. (A) <t>IMRT-N,</t> (B) IMRT-BM, (C) IMRT-LS+OC, <t>(D)</t> <t>VMAT-LS+OC,</t> and (E) HT-LS+OC plans.
Fixed Field Imrt, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/fixed-field imrt/product/TomoTherapy
Average 90 stars, based on 1 article reviews
fixed-field imrt - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
TomoTherapy imrt
Typical dose distributions of the five plans in cervical cancer. (A) <t>IMRT-N,</t> (B) IMRT-BM, (C) IMRT-LS+OC, <t>(D)</t> <t>VMAT-LS+OC,</t> and (E) HT-LS+OC plans.
Imrt, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/imrt/product/TomoTherapy
Average 90 stars, based on 1 article reviews
imrt - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

90
TomoTherapy tomotherapy tomo
Typical dose distributions of the five plans in cervical cancer. (A) <t>IMRT-N,</t> (B) IMRT-BM, (C) IMRT-LS+OC, <t>(D)</t> <t>VMAT-LS+OC,</t> and (E) HT-LS+OC plans.
Tomotherapy Tomo, supplied by TomoTherapy, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/tomotherapy tomo/product/TomoTherapy
Average 90 stars, based on 1 article reviews
tomotherapy tomo - by Bioz Stars, 2026-06
90/100 stars
  Buy from Supplier

imrt  (Elekta)
86
Elekta imrt
Typical dose distributions of the five plans in cervical cancer. (A) <t>IMRT-N,</t> (B) IMRT-BM, (C) IMRT-LS+OC, <t>(D)</t> <t>VMAT-LS+OC,</t> and (E) HT-LS+OC plans.
Imrt, supplied by Elekta, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/imrt/product/Elekta
Average 86 stars, based on 1 article reviews
imrt - by Bioz Stars, 2026-06
86/100 stars
  Buy from Supplier

Image Search Results


Dose distribution maps of patient 3 treated with TBI. The radiotherapy plan of this patient was helical tomotherapy-TBI. The red range in the map is the isodose line of 13.2 Gy. The yellow range is the isodose line of 12.0 Gy. The yellow-green range is the isodose line of 11.4 Gy. The green range is the isodose line of 10.8 Gy. The blue range is the isodose line of 8.0 Gy. TBI, total body irradiation.

Journal: Molecular Medicine Reports

Article Title: Comparison of target volume and clinical effects of four radiotherapy plans for acute lymphoblastic leukemia prior to hematopoietic stem cell transplantation

doi: 10.3892/mmr.2018.9228

Figure Lengend Snippet: Dose distribution maps of patient 3 treated with TBI. The radiotherapy plan of this patient was helical tomotherapy-TBI. The red range in the map is the isodose line of 13.2 Gy. The yellow range is the isodose line of 12.0 Gy. The yellow-green range is the isodose line of 11.4 Gy. The green range is the isodose line of 10.8 Gy. The blue range is the isodose line of 8.0 Gy. TBI, total body irradiation.

Article Snippet: Compared with the conventional IMRT plan, the tomotherapy plan exhibits a higher conformity and increased protection to lung tissue, which may effectively reduce the incidence of radiation pneumonia ( ).

Techniques: Irradiation

Dose volume histogram of patient 9 treated with helical tomotherapy-total marrow and lymphatic irradiation. The light pink and darker pink lines on the bottom left panel represented the left and right crystalline lens, respectively. The pink and purple lines in the middle are the left and right lungs, respectively. The red, light blue and orange lines on the right are PTV bone, PTV lymph node and PTV spleen, respectively. PTV, planning target volume.

Journal: Molecular Medicine Reports

Article Title: Comparison of target volume and clinical effects of four radiotherapy plans for acute lymphoblastic leukemia prior to hematopoietic stem cell transplantation

doi: 10.3892/mmr.2018.9228

Figure Lengend Snippet: Dose volume histogram of patient 9 treated with helical tomotherapy-total marrow and lymphatic irradiation. The light pink and darker pink lines on the bottom left panel represented the left and right crystalline lens, respectively. The pink and purple lines in the middle are the left and right lungs, respectively. The red, light blue and orange lines on the right are PTV bone, PTV lymph node and PTV spleen, respectively. PTV, planning target volume.

Article Snippet: Compared with the conventional IMRT plan, the tomotherapy plan exhibits a higher conformity and increased protection to lung tissue, which may effectively reduce the incidence of radiation pneumonia ( ).

Techniques: Irradiation

Structure definition and dose distribution for one MPM patient (Step & Shoot IMRT). In the coronar projection ( a ), the inclusion of the EPP incisions into the target volume are marked by white arrows. The sagittal projection ( b ) shows the caudal extension of the target volume with sparing of the liver and the kidney. In the two transverse slices the sparing of the heart ( c ) and again liver and kidney ( d ) can be seen

Journal: Radiation Oncology (London, England)

Article Title: Long-term results in malignant pleural mesothelioma treated with neoadjuvant chemotherapy, extrapleural pneumonectomy and intensity-modulated radiotherapy

doi: 10.1186/s13014-015-0575-5

Figure Lengend Snippet: Structure definition and dose distribution for one MPM patient (Step & Shoot IMRT). In the coronar projection ( a ), the inclusion of the EPP incisions into the target volume are marked by white arrows. The sagittal projection ( b ) shows the caudal extension of the target volume with sparing of the liver and the kidney. In the two transverse slices the sparing of the heart ( c ) and again liver and kidney ( d ) can be seen

Article Snippet: Step&shoot-IMRT (“IMRT”) vs. helical tomotherapy-IMRT (“Tomo”) shows no significant difference regarding a overall survival, b locoregional control and c distant control Fig. 4 Kaplan-Meier curves separated for histology.

Techniques:

Kaplan-Meier curves separated for type of radiation treatment. Step&shoot-IMRT (“IMRT”) vs. helical tomotherapy-IMRT (“Tomo”) shows no significant difference regarding a overall survival, b locoregional control and c distant control

Journal: Radiation Oncology (London, England)

Article Title: Long-term results in malignant pleural mesothelioma treated with neoadjuvant chemotherapy, extrapleural pneumonectomy and intensity-modulated radiotherapy

doi: 10.1186/s13014-015-0575-5

Figure Lengend Snippet: Kaplan-Meier curves separated for type of radiation treatment. Step&shoot-IMRT (“IMRT”) vs. helical tomotherapy-IMRT (“Tomo”) shows no significant difference regarding a overall survival, b locoregional control and c distant control

Article Snippet: Step&shoot-IMRT (“IMRT”) vs. helical tomotherapy-IMRT (“Tomo”) shows no significant difference regarding a overall survival, b locoregional control and c distant control Fig. 4 Kaplan-Meier curves separated for histology.

Techniques: Control

Typical dose distributions of the five plans in cervical cancer. (A) IMRT-N, (B) IMRT-BM, (C) IMRT-LS+OC, (D) VMAT-LS+OC, and (E) HT-LS+OC plans.

Journal: Frontiers in Oncology

Article Title: Which Bone Marrow Sparing Strategy and Radiotherapy Technology Is Most Beneficial in Bone Marrow-Sparing Intensity Modulated Radiation Therapy for Patients With Cervical Cancer?

doi: 10.3389/fonc.2020.554241

Figure Lengend Snippet: Typical dose distributions of the five plans in cervical cancer. (A) IMRT-N, (B) IMRT-BM, (C) IMRT-LS+OC, (D) VMAT-LS+OC, and (E) HT-LS+OC plans.

Article Snippet: Then, we determined the optimal technology for the BMS-IMRT, including fixed-field IMRT (FF-IMRT), volumetric-modulated arc therapy (VMAT), and helical tomotherapy (HT).

Techniques:

The comparison of planning target volume, bone marrow volume, and treatment time in BM-sparing IMRT. Typical dose-volume histograms for planning target volume (purple) and bone marrow (green) (A+C) , histogram for bone marrow volume (B+D) with three different dose limitation strategies for pelvic radiotherapy: IMRT-N, IMRT-BM, and IMRT-LS+OC and three different radiotherapy technologies: IMRT-LS+OC, VMAT-LS+OC, and HT-LS+OC. Typical scatter diagram for treatment time (E) with three different radiotherapy technologies. * P < 0.05, ** P < 0.01, *** P < 0.001. ns: P > 0.05, no statistical significance.

Journal: Frontiers in Oncology

Article Title: Which Bone Marrow Sparing Strategy and Radiotherapy Technology Is Most Beneficial in Bone Marrow-Sparing Intensity Modulated Radiation Therapy for Patients With Cervical Cancer?

doi: 10.3389/fonc.2020.554241

Figure Lengend Snippet: The comparison of planning target volume, bone marrow volume, and treatment time in BM-sparing IMRT. Typical dose-volume histograms for planning target volume (purple) and bone marrow (green) (A+C) , histogram for bone marrow volume (B+D) with three different dose limitation strategies for pelvic radiotherapy: IMRT-N, IMRT-BM, and IMRT-LS+OC and three different radiotherapy technologies: IMRT-LS+OC, VMAT-LS+OC, and HT-LS+OC. Typical scatter diagram for treatment time (E) with three different radiotherapy technologies. * P < 0.05, ** P < 0.01, *** P < 0.001. ns: P > 0.05, no statistical significance.

Article Snippet: Then, we determined the optimal technology for the BMS-IMRT, including fixed-field IMRT (FF-IMRT), volumetric-modulated arc therapy (VMAT), and helical tomotherapy (HT).

Techniques: Comparison

Dosimetric parameters for PTV and main OARs in  FF-IMRT,  VMAT, and TOMO plans.

Journal: Frontiers in Oncology

Article Title: Which Bone Marrow Sparing Strategy and Radiotherapy Technology Is Most Beneficial in Bone Marrow-Sparing Intensity Modulated Radiation Therapy for Patients With Cervical Cancer?

doi: 10.3389/fonc.2020.554241

Figure Lengend Snippet: Dosimetric parameters for PTV and main OARs in FF-IMRT, VMAT, and TOMO plans.

Article Snippet: Then, we determined the optimal technology for the BMS-IMRT, including fixed-field IMRT (FF-IMRT), volumetric-modulated arc therapy (VMAT), and helical tomotherapy (HT).

Techniques: